Power supply:
|
-
24VDC (9.0VDC ... 32.0VDC)
-
allowable voltage variation at 24VDC
rated voltage according to EN 50155: Class S2
-
reverse battery protection -32 ...
+32VDC
-
circular connector with pin-out
according to DIN 41524 socket, 3 poles metal housing, screw plug
-
circular connector with pin-out
according to DIN 41524 plug, 3 poles metal housing, screw plug (existing
only for analysers with RS-485 interface)
|
|
Current consumption
including all sensors: |
-
<=0.50A at 9VDC<=0.12A at 24VDC
|
|
Ambient temperature in
operation: |
-
-25°C to +75°C (-13°F to +167°F)
|
|
Storing temperature:
|
-
-40°C to +85°C (-40°F to +185°F)
|
|
Relative humidity:
|
|
|
Electromagnetic
emission: |
-
EN 50121-3-2 valid for analysers
with the following interfaces:
|
|
Immunity to
electromagnetic disturbance: |
-
EN 50121-3-2 valid for analysers
with the following interfaces:
-
IBIS
-
RS-232 (restricted)
-
RS-485
-
EN 61000-6-2 valid for analysers
with the following interfaces:
|
|
Classification of
mechanical environmental conditions: |
-
class 5M2 according to
EN 60721 Part 3-5
-
class 1, category A according to
EN 61373
|
|
Loading of software:
|
-
with a laptop/PC through the
analyser interface
|