
Communication between the on-board computer and the analysers with the J1708 interface is not described in this documentation, but in the Iris documentation "Universal J1708-IRMA-Protocol". Communication between the on-board computer and the analysers with IBIS, RS-485 and RS-232 interfaces takes place using the data records defined in the VDV 300 (IBIS) guideline.
Iris-GmbH has added further data records to these data records in order to make working with the IRMA passenger counting system more convenient. In addition, all call data records of the on-board computer have been extended by a door address in order to differentiate between several doors. Call data records without door address are not answered by IRMA.
The table lists all available data records:
Algorithm of the "counts" of the test function "Simulation of passenger change"
The sum of boarding and alighting passengers at each door is 100. The number of boarding passengers is reduced by 1 and the number of alighting passengers increased by 1 by each opening of the door.
|
|
"Counts" in the analyser |
|
|
In |
Out |
|
|
with active test function with the door closed after the 1st opening of the door after the 2nd opening of the door after the 3rd opening of the door after the 99th opening of the door after the 100th opening of the door after the 101st opening of the door |
0 |
0 |
Notes on the test function
|
Call data records of the on-board computer / Meaning |
Response data records of the analyzer / Meaning |
||||
|
DS0801 |
bVH |
Polling of software version |
DS1801 |
bVX |
Transmission of software version |
|
- |
bPH |
Polling of parameterization |
- |
bPX |
Transmission of the way of setting parameters |
|
DS080 |
bTH |
Door was opened |
DS181 |
bF |
Acknowledgement and identification |
|
DS081 |
bMH |
Door was closed |
DS181 |
bF |
Acknowledgement and identification |
|
DS084 |
bSH |
Polling of the device
status |
DS184 |
|
Transmission of the device status |
|
bS0 |
IRMA in order, no measuring result available |
||||
|
bS1 |
IRMA in order, new measuring result available |
||||
|
bS2 |
IRMA in order, measurement not yet finished or counts not yet transferred into the output buffer |
||||
|
bS3 |
IRMA fault |
||||
|
bS4 |
IRMA sabotaged |
||||
|
- |
bRH |
Polling of the device
status |
- |
|
Transmission of the device status |
|
bR00 |
IRMA in order, no measuring result available |
||||
|
bR01 |
IRMA in order, new measuring result available |
||||
|
bR02 |
IRMA in order, measurement not yet finished or counts not yet transferred into the output buffer |
||||
|
bR03 |
IRMA fault |
||||
|
bR04 |
IRMA sabotaged |
||||
|
DS082 |
bFH |
Travel started |
DS181 |
bF |
Acknowledgement and identification |
|
DS083 |
bEH |
Polling of counts |
DS183 |
bEEAA |
Transmission of the counts · EE = 2 digits for the number of boarding passengers · AA = 2 digits for the number of alighting passengers |
|
- |
bWH |
Polling of door status |
- |
|
Transmission of the door status (door open or door closed) |
|
b0 |
Door is open or moving |
||||
|
b1 |
Door is closed |
||||
|
- |
bYH |
Activation of the test function "Simulation of passenger change" |
DS181 |
bF |
Acknowledgement and identification |
|
- |
bZH |
Deactivation of the test function "Simulation of passenger change" |
DS181 |
bF |
Acknowledgement and identification |
H = door address