Home ] Products - Index ] Services ] Next ] Previous ] Contact ]

 

 

 

5.0 IRMA Communication System

Communication between the on-board computer and the analysers with the J1708 interface is not described in this documentation, but in the Iris documentation "Universal J1708-IRMA-Protocol".  Communication between the on-board computer and the analysers with IBIS, RS-485 and RS-232 interfaces takes place using the data records defined in the VDV 300 (IBIS) guideline. 

Iris-GmbH has added further data records to these data records in order to make working with the IRMA passenger counting system more convenient.  In addition, all call data records of the on-board computer have been extended by a door address in order to differentiate between several doors.  Call data records without door address are not answered by IRMA.

The table lists all available data records:

Algorithm of the "counts" of the test function "Simulation of passenger change"

The sum of boarding and alighting passengers at each door is 100.  The number of boarding passengers is reduced by 1 and the number of alighting passengers increased by 1 by each opening of the door.

 

"Counts" in the analyser

In

Out

with active test function with the door closed

after the 1st opening of the door

after the 2nd opening of the door

after the 3rd opening of the door

after the 99th opening of the door

after the 100th opening of the door

after the 101st opening of the door

0
100
99
98

2
1
0

0
0
1
2

98
99
100

Notes on the test function

 

Call data records of the on-board computer / Meaning

Response data records of  the analyzer / Meaning

DS0801

bVH

Polling of software version

DS1801

bVX

Transmission of software version

-

bPH

Polling of parameterization

-

bPX

Transmission of the way of setting parameters

DS080

bTH

Door was opened

DS181

bF

Acknowledgement and identification

DS081

bMH

Door was closed

DS181

bF

Acknowledgement and identification

DS084

bSH

Polling of the device status
(Not possible with RS-485 in half-duplex mode)

DS184

 

Transmission of the device status

bS0

IRMA in order, no measuring result available

bS1

IRMA in order, new measuring result available

bS2

IRMA in order, measurement not yet finished or counts not yet transferred into the output buffer

bS3

IRMA fault

bS4

IRMA sabotaged

-

bRH

Polling of the device status
(Possible only with RS-485 in half-duplex and full-duplex mode)

-

 

Transmission of the device status

bR00

IRMA in order, no measuring result available

bR01

IRMA in order, new measuring result available

bR02

IRMA in order, measurement not yet finished or counts not yet transferred into the output buffer

bR03

IRMA fault

bR04

IRMA sabotaged

DS082

bFH

Travel started

DS181

bF

Acknowledgement and identification

DS083

bEH

Polling of counts

DS183

bEEAA

Transmission of the counts

·         EE = 2 digits for the number of boarding passengers

·         AA = 2 digits for the number of alighting passengers

-

bWH

Polling of door status

-

 

Transmission of the door status (door open or door closed)

b0

Door is open or moving

b1

Door is closed

-

bYH

Activation of the test function "Simulation of passenger change"

DS181

bF

Acknowledgement and identification

-

bZH

Deactivation of the test function "Simulation of passenger change"

DS181

bF

Acknowledgement and identification

 H = door address